תיאור
Extremely high quality, durable and flexible – these are the characteristics of the RUMED® Premium-Line of stainless steel. Thanks to the variety of options and accessories, the precision test cabinets can be configured almost boundlessly for any kind of climatic test.
No matter if stability test in pharmacy, cultivation of test plants, or artificial ageing of products – the influence of temperature, humidity, light and CO2 on the specimen can be tested reliably by means of RUMED®s Stainless Steel Premium-Line. We offer a selection of 6 test room volumes from 210 l to 1700 l, which is unique on the market. Particularly the large-volume appliances with only small space requirements in the laboratory have an extremely good cost-benefit ratio relating to the volume. The next pages will give more details concerning the standard execution and the possible options.
General view of the most important advantages:
- Test room volumes from 210 l to 1700 l
- Test room and external housing of corrosion-resistant stainless steel
- Suitable for installation in a clean room, easy cleaning
- Temperature ranges from -30 °C to +80 °C
- High operating convenience, intuitive handling by means of the Control2015 touch
- Eco-friendly refrigerants
- Energy-saving lighting and refrigeration technology
- Noise minimization by speed-controlled compressor fan
- Extremely durable
- Possibility of calibration and validation
Type | P 210 | P 350 | P 530 | P 850 | P1060 | P1700 |
Volume (l) | 210 | 350 | 530 | 850 | 1060 | 1700 |
Standard minimum temperature | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C |
Standard maximum temperature | +50 °C | +50 °C | +50 °C | +50 °C | +50 °C | +50 °C |
Temperature deviation in time ( °C) | ±0,5 °C | ±0,5 °C | ±0,5 °C | ±0,5 °C | ±0,5 °C | ±0,5 °C |
Height (mm) | 600 | 990 | 1500 | 1500 | 1500 | 1500 |
Width (mm) | 610 | 610 | 610 | 610 | 2 x 610 | 2 x 610 |
Depth (mm) | 585 | 585 | 585 | 935 | 585 | 935 |
Number of shelves (standard delivery scope) | 2 | 3 | 3 | 3 | 6 | 6 |
Maximum load per shelf (kg) | 25 | 25 | 25 | 25 | 25 | 25 |
Unit | ||||||
Height (mm) | 1180 | 1600 | 2105 | 2105 | 2105 | 2105 |
Width (mm) | 730 | 730 | 730 | 730 | 1460 | 1460 |
Depth (mm) | 820 | 820 | 820 | 1170 | 820 | 1170 |
Electric connection (V/Hz) | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 |
Net weight of standard unit (kg) | 80 | 125 | 160 | 200 | 260 | 350 |
Options:
Heated glass panel doorThe triple glazed glass panel door always ensures an optimum view into the test room. A pane heating avoids formation of condensate. |
|
Internal glass doorAnother option: the internal glass door. When the appliance door is open, it allows a visual check of the specimen – without any unnecessary disturbance of the climate in the test room. |
|
Plate evaporatorThe stainless steel plate evaporator is always recommendable, whenever acid resistance is required, such as for Drosophila cultivation. |
|
Reinforced insertion gridsThe reinforced stainless steel grid shelves are recommendable for building material testing or beer Forcier tests. Their maximum carrying capacity is up to 50 kg. |
|
Condensate collecting panCollecting pan for dew water or condensate. It can be easily withdrawn to the front. Order No.: P9910-01 |
|
Tubular portA 45 mm duct in the side panel allows insertion of measuring lines and hoses into the test room. Delivery including cover. For the Eco-Line or as additional duct in the Premium-Line. |
|
Closing plugGas-tight closing plug, matching to the tubular port. The gasket system with a flexibility in the range of 4 mm to 23 mm is based on a rubber module with removable skins and can be adapted to the cables, tubes etc. in different sizes. |
|
Fresh air rosette2 Fresh air rosettes, air flow rate adjustable, located in the upper and lower area of the test room, ensure the fresh air supply into the test room. Application: Plants, test animals. |
|
Steering rollersMobile version of the test cabinet with 4 steering rollers, 2 of them lock-type with brake. |
|
SocketTest room socket for connection of shakers, magnetic mixers etc. in the test room. The switching-on times can be freely programmed by means of the Control2015 touch |
|
Door releaseElectromagnetic door release by means of the Control2015 touch. Door unlocking only after successful authorization with entry in the logbook (name, date, time). |