לקוחות יקרים, בימי חג הפסח 22-29/4/24  אנו עובדים במתכונת מצומצמת. נשוב לפעילות מלאה ביום שלישי 30/04/24.      חג שמח!

Twelve Channel EVOLVE Manual Pipettes

Traditional pipettes utilize a single rotating plunger to set the volumes. This approach makes frequent adjustment of volumes tedious, especially when switching from lower to higher volumes.

To overcome this pain point, the EVOLVE manual pipette has been designed with three adjustable dials to rapidly set volumes. This revolutionary approach reduces repetitive stress injuries and allows users to set volumes in a fraction of the time it takes with a traditional manual pipette.

תיאור

How it works

The EVOLVE manual pipette features three adjustable dials to rapidly set volumes. This approach allows users to set volumes more than ten times faster than standard manual pipettes.

Quick Set Dials

Unlike traditional pipeattes which utilize a single rotating plunger to set volumes, EVOLVE features one dial for setting each of three volume digits. This is the same convenient method used to unlock three dial combination locks.

Simply depress and twist the plunger to release spring tension from the volume dials. This allows users to freely adjust all dials in either direction. Once set, twist and return the plunger to the up position.

Volumes set on traditional manual pipettes can often change while pipetting due to unintentional plunger turns. The EVOLVE Quick Set Dial design prevents inadvertent volume drift due to plunger movements while pipetting.

GripTip pipette tips which never leak or fall off

GripTips are always firmly attached and perfectly aligned, regardless of how many side well touch offs are performed. You no longer have to hammer your pipette tips on or worry about pipette tips falling off!

1) LOBES

2) O-RING SEAL

3) RIM SNAPS OVER THE LOBES

4) SHOULDER

The rim (3) of the GripTips will snap over the Multi-Lobes (1), attaching firmly. As a result, GripTips will never accidently fall off.

A shoulder (4) provides a positive stop to prevent over-tightening of the tip. The GripTip can only be attached up to that point and no further, ensuring that all tips are at the same height. As a result, the tip is either on or off, but nothing in between.

Interchangeable Plunger Spring Assemblies

Two differently sized plunger springs allow users to customize the force needed to depress the plunger to their preference. The controlled plunger spring option allows users to slow the aspiration and dispense speeds resulting in improved pipetting technique and results.

The controlled plunger spring is compatible with all single channel EVOLVE pipettes except the 5 ml model. Changing the spring is completed in seconds.

INTEGRA Linear Stand

Storing pipettes upright is important to prevent liquid or debris from entering the tip fitting. Proper storage For The EVOLVE also extends the life of a pipette.

The INTEGRA linear stand is ideal for hanging EVOLVE pipettes up off the lab bench. Up to twelve manual pipettes can be placed on a linear stand. EVOLVE shelf hooks are also available for proper storage.

For the EVOLVE Specifications click HERE

Instrument  Volume range  Part No.
  1 – 10 μl 3032
5 – 50 μl 3034
10 – 100 μl 3035
20 – 200 μl 3036
השאירו לנו הודעה

שירות טכני: 08-683-6306
מכירות: 072-395-0508
מייל: info@medent.co.il

להצעה מהירה דילוג לתוכן